Vit dagføra vøruupplýsingarnar. Vit fara ígjøgnum allar vørulýsingarnar í vørusavninum. Upplýsingarnar um nýtsluøki og tilfar, sum vøran kann brúkast til, kunnu vera skeivar, meðan vit skráseta rætta tilfarið fyri hvørja vøru. Ert tú í iva, spyr tín kontaktpersón hjá A4.
Electrical crafts, industry, vehicle workshops, construction
The innovative two-pole voltage tester with a wide range of functions (voltage testing, continuity testing, resistance measurement, rotating field display, RCCB tripping etc.) impresses with its user-friendly handling and robust design, meeting all the requirements that a specialist puts on modern voltage testers. The highest safety level of CAT IV 1,000 V means that it is also suitable for measurements on hybrid and electric vehicles as well as photovoltaic systems. With a wide range of functions (voltage testing, continuity testing, resistance measurement, rotary field display, RCCB tripping etc.) Measuring range selection: automatic Single-pole phase testing: yes Two-pole rotary field testing: yes, at > 200 V AC Measuring point illumination: via white LED
Fyrimunir
- Easy to use, quick reading of measurement results
- One-hand operation
- Wide range of services
- CAT IV 1000 V, optimal one-hand operation for rotating field strength measurement
- Indication of voltages also possible without battery
Góð ráð
- Voltage-free continuity testing possible.
Batteries
Faklig nærlýsing
| Battery designation | 1.5 V Micro AAA |
| Continuity testing, max. electrical resistance | 200 kOhm |
| Continuity testing, min. electrical resistance | 0 kOhm |
| Continuity testing, min./max. electrical resistance | 0-200 kOhm |
| Display | Optical, LEDs |
| EN standard | 61243-3 |
| Height | 20 mm |
| Included in delivery | Batteries |
| IP protection class | IP 65 |
| Length | 300 mm |
| Length x width x height | 300 x 75 x 20 mm |
| Max. AC voltage range | 1000 V |
| Max. DC voltage range | 1400 V |
| Max. frequency display | 500 Hz |
| Min. AC voltage range | 6 V |
| Min. DC voltage range | 6 V |
| Min. frequency display | 0 Hz |
| Min. voltage for phase testing | 100 V/AC |
| Min./max. frequency display | 0-500 Hz |
| Min./max. voltage range AC | 6-1000 V |
| Min./max. voltage range DC | 6-1400 V |
| Number of rechargeable batteries/batteries | 2 PCS |
| Overvoltage protection category | CAT IV/1000 V |
| Polarity testing | Yes |
| Switchable load | 30 mA at 230V/AC |
| Width | 75 mm |
Væntað veiting: 29.–30. sep.
Bílegg í seinasta lagi mikudagin kl. 23:59 · bíleggingin verður send til Reca hósdagin
RECA voltage tester LED
The innovative two-pole voltage tester with a wide range of functions (voltage testing, continuity testing, resistance measurement, rotating field display, RCCB tripping etc.) impresses with its user-friendly handling and robust design, meeting all the requirements that a specialist puts on modern voltage testers. The highest safety level of CAT IV 1,000 V means that it is also suitable for measurements on hybrid and electric vehicles as well as photovoltaic systems. With a wide range of functions (voltage testing, continuity testing, resistance measurement, rotary field display, RCCB tripping etc.) Measuring range selection: automatic Single-pole phase testing: yes Two-pole rotary field testing: yes, at > 200 V AC Measuring point illumination: via white LED
| Vørunummar | 0705901022 |
| EAN | 4029484916290 |
| Pakkieind | 1 stk |
| Battery designation | 1.5 V Micro AAA |
| Continuity testing, max. electrical resistance | 200 kOhm |
| Continuity testing, min. electrical resistance | 0 kOhm |
| Continuity testing, min./max. electrical resistance | 0-200 kOhm |
| Display | Optical, LEDs |
| Veitari | RECA NORM |