Updated product information. We are reviewing every description in the catalogue. The application area and the materials listed may be incorrect while we set the correct materials on all articles. If in doubt, ask your contact at A4.
- Aluminium
- Composite
The KWS 50 mm continuous pipe flashing is used to seal combustible pipelines and aluminium composite pipes with synthetic rubber in solid ceilings from 150 mm and solid walls as well as sealing off light partition walls from 100 mm with a fire resistance of 90 minutes.
The KWS 50 mm continuous pipe flashing is an intumescent fire protection fabric and is used as a continuous pipe flashing to restore the fire safety of solid wall and ceiling structures that have openings for combustible pipes, aluminium composite pipes, cables and cable bundles in EIR/flexible pipes or cable bundles for split air-conditioning units.
Advantages
- Versatile - one article for single pipe feedthroughs and KWS combination partitions
- Maintenance-free - can be installed in confined spaces, attach using standard tape
- The fabric material is highly flexible and therefore easy to process
- Can be easily cut using a knife or scissors
- Simplified logistics and storage - requires little space in the construction site vehicle
- Economic solution - simple design and fast installation
- Can be used indoors and in protected outdoor areas
- 15 metres per roll
- Free from solvents, silicone, halogen and plasticisers; VOC emissions class A+
Advice
- Please observe the respective proof of usability before use and fit according to specifications!
Technical specifications
| Building material class | B2 - Normally inflammable |
| Conditions to maintain shelf life from production | dry storage area |
| Length of roll | 15 m |
| Thickness | 2 mm |
| Width | 50 mm |
Expected delivery: 29–30 Sep
Order by Wednesday 23:59 · sent to Reca on Thursday
RECA KWS internal continuous pipe collar, 50 mm, fabric, 15 m
The KWS 50 mm continuous pipe flashing is an intumescent fire protection fabric and is used as a continuous pipe flashing to restore the fire safety of solid wall and ceiling structures that have openings for combustible pipes, aluminium composite pipes, cables and cable bundles in EIR/flexible pipes or cable bundles for split air-conditioning units.
| Article number | 0839470000 |
| EAN | 4066115005527 |
| Pack unit | 1 pc |
| Building material class | B2 - Normally inflammable |
| Conditions to maintain shelf life from production | dry storage area |
| Length of roll | 15 m |
| Thickness | 2 mm |
| Width | 50 mm |
| Supplier | RECA NORM |